System down right now? Message our emergency line with your site, what stopped and the area.

Call +20 110 006 3316

T11Rack planner

Will it fit in the rack, and can the room cool it?

Add equipment and watch the rack elevation: units, weight, power and heat.

Rack layout

Default: a small office rack with PoE switch, firewall, NVR and UPS.

This planner needs JavaScript. Send us your equipment list and we will draw the rack layout: request an SLA review or message us on WhatsApp.

Request an SLA

More about this tool

01How it's calculated: Four totals and a layout rule

A rack plan fails on space, weight, power or heat. We add up all four and place the heavy items low.

  1. 01

    Rack units

    One rack unit (U) is 44.45 mm. Each item's height times its quantity, summed. Above 80% full we warn: cable managers, airflow and next year's switch need space.

    U = Σ qty × height

  2. 02

    Weight and power

    Weight is compared with the rack's rated load (typical: 50–60 kg for wall cabinets, 400–800 kg for floor racks; use the datasheet). Power is converted to amps at 220 V and checked against 80% of a 16 A circuit.

    A = W ÷ 220 · limit = 0.8 × 16 A × 220 V ≈ 2,816 W

  3. 03

    Heat and layout

    All electrical power in the rack becomes heat. UPS units, batteries and anything 15 kg per U or heavier go to the bottom for stability; the rest fills from the top.

    BTU/h = W × 3.412

Rack unit per EIA-310. 1 W = 3.412 BTU/h. Weights and watts are typical values; datasheets take priority.

Questions

01What size rack do I need for a small office?

Most small offices with one or two switches, patch panels, a firewall, an NVR and a small UPS fit in a 12U wall cabinet. Add servers, a rack UPS with battery packs, or more than 48 cable drops and you are into a 22U floor rack. Leave about a quarter of the space free.

02How do I calculate the heat from a server rack?

Add up the watts of everything in the rack and multiply by 3.412 to get BTU per hour. A rack drawing 1,000 W gives off about 3,400 BTU/h, roughly the output of a small 1.5 HP split air conditioner, which is why closed comms rooms need their own cooling.

03Where should the UPS go in the rack?

At the bottom. UPS units and battery packs are the heaviest items, and putting them low keeps the rack stable and stops a wall cabinet pulling away from the wall. Patch panels and switches go at the top, close to where the cables come in.

Want the rack built neatly and kept that way?

We build racks with labelled patching, proper power and cooling, and keep them maintained under an SLA.

Request an SLA WhatsApp us